MK Series High Voltage AC/DC Power Supplies

MK Series High Voltage AC_DC Power Supplies XP Glassman
 
  • SW11404
Input Voltage 90-253 VAC; Max. Output Voltage 1-60 kVDC; Max. Power 75 W; Efficiency >75%;... more
Product information "MK Series High Voltage AC/DC Power Supplies"

Input Voltage 90-253 VAC; Max. Output Voltage 1-60 kVDC; Max. Power 75 W; Efficiency >75%; Voltage Regulation <0.005% + 1 mV/mA; Current Regulation <0.1%

XP Glassman’s MK Series of 75 W high voltage AC/DC power supplies are air-insulated, fast-response, chassis-mount units with tight regulation and low arc discharge currents. A broad range of models is available with output voltage ranges from 0 to 1 kVDC through 0 to 60 kVDC.

The MK Series’ current regulation is unequalled in a module of this price range. For example, the regulation from short circuit to rated voltage for the 15 kV, 5 mA model is +2.5 µA. Overload, short circuit and arc protection is provided by automatic current regulation and by careful surge limiting design. XP Glassman’s “Air Insulated” designs are completely serviceable, these modules are not epoxy block “throw-away” power supplies.

The MK Series’ standard operation mode is constant voltage/current with less than 800 mJ of stored energy. A “multi-mode” operation mode permits maximum user flexibility. Local voltage or current control is user selectable, and the MK Series power supplies feature remote voltage and/or current control via 0 to +10 V signal or potentiometers. External interlock terminals allow enable/disable of the power supply via TTL signal.

Standard accessories for the MK Series include a detachable 2,4 m shielded output cable, mating control connector and line cord.

The MK Series supplies with 230 VAC input option (198 to 253 VAC RMS, 48 to 63 Hz) are fully compliant with the following European directives:

  • EN61000-3-2, Line Harmonics
  • EN61010/ IEC61010, Safety
  • EN61000-6-4, Conducted and Radiated Emissions
  • EN61000-6-2:2005, Conducted and Radiated Immunity
  • 2011/65/EU, Restriction of the Use of Hazardous Substances (RoHS)

Key Features:

  • Compact Module
  • Air Insulated
  • Low Ripple: <0.03% RMS of Rated Voltage + 0.5 V at Full Load
  • Tight Regulation
  • Static Voltage Regulation: <0.005% + 1 mV/mA, Line and Load
  • Current Regulation: <0.1% From Short Circuit to Rated Voltage at Any Load Condition
  • Constant Voltage/Constant Current Operation
  • Maximum Output Power: 75 W
  • Maximum Output Voltage: 1 to 60 kVDC
  • Maximum Output Current: 1.2 to 75 mA
  • Input Voltage: 105 to 125, 198 to 253 VAC RMS, 48 to 420 Hz, Single Phase
  • Efficiency: >75% at Full Load
  • Output Voltage Accuracy: 1% of Setting + 0.5% of Rated
  • Stored Energy: 200 mJ (10 kV Model), 1 J (50 kV Model)
  • Voltage Monitor: 0 to +10 VDC Signal for 0 to Rated Voltage
  • Current Monitor: 0 to +10 VDC Signal for 0 to Rated Current
  • Stability: 0.01%/h After 0.5 h Warm-up, 0.05% per 8 h
  • Polarity: Positive or Negative Polarity With Respect to Chassis Ground
  • Protection: Against All Overload Conditions, Including Arcs and Short Circuits
  • Remote Controls: DB25S D-Sub Connector and Mating Plug Provided for All Control Input Functions
  • Control Input Functions: +10 V Reference, External Interlock, Current Monitor, Current Program, Voltage Monitor, Voltage Program, TTL, Ground, Local Control
  • Options: 100, 230 VAC Input, 400 Hz Input, Control and Monitor via RS232, USB, Ethernet
  • 3 Year Warranty
  • Approvals: IEC61010-1:2010; EN61000-6-4:2007, Class A EN61000-6-2:2005
  • Operating Temperature: -10 to +60 °C
  • Dimensions: 120.6 x 131.7 x 279.4 mm

Applications: High Voltage, High Power Applications; Photonics; Healthcare (Analytical, Diagnostics, Detectors); Industrial; Semiconductor Manufacturing; Research; Other

Product Group: High Voltage AC/DC Power Supplies
Manufacturer Series Name: MK Series
Related links to "MK Series High Voltage AC/DC Power Supplies"
Read, write and discuss reviews... more
Customer evaluation for "MK Series High Voltage AC/DC Power Supplies"
Write an evaluation
Evaluations will be activated after verification.

The fields marked with * are required.

Viewed