The product range offers the measurement of currents from microamps to 20K amps, at frequencies ranging from 0.5 Hz to 500 MHz. The output signal of the transformer is an accurate voltage waveform representation of the measured current, which can be analyzed on an oscilloscope, RF power meter, spectrum analyzer or custom interface circuitry. Offering superior performance and quality, the transformers are available in 5 case sizes, can be terminated with BNC or SMA connectors and offer sensitivity range providing environmental application flexibility. All transformers can be shipped with certificate of calibration and factory test data, ensuring optimum Ievels of performance are realized.

• Laser and Plasma research • EMC and EMI research • Semiconductor gate switching • Power system barmollies and transients • Lightning research and simulation testing • Capacitor and electrostatic discharges • Corona wire discharge • Partial Discharge measurement • Critical monitoring of current fluctuations

AMS Technologies has invested into the pickaCT program offering customers off the shelf availability of a large number of different HF current transformers. The product range offers the measurement of currents from microamps to 20K amps, at frequencies ranging from 0.5 Hz to 500 MHz.  The selection guide to these preferred current transformers can be found on the next page or online:  www.amstechnologies-webshop.com/current-transformer

For large volume applications we recommend to call your regional AMS Technologies office, so that we can tailor a solution based on your technical needs.

Super High Performance Lab-Grade Current Transformer The product range offers the measurement of currents from microamps to 20K amps, at frequencies ranging from 0.5 Hz to 500 MHz. The output... read more »
Close window
High Precision HF Current Transformers

Super High Performance Lab-Grade Current Transformer

The product range offers the measurement of currents from microamps to 20K amps, at frequencies ranging from 0.5 Hz to 500 MHz. The output signal of the transformer is an accurate voltage waveform representation of the measured current, which can be analyzed on an oscilloscope, RF power meter, spectrum analyzer or custom interface circuitry. Offering superior performance and quality, the transformers are available in 5 case sizes, can be terminated with BNC or SMA connectors and offer sensitivity range providing environmental application flexibility. All transformers can be shipped with certificate of calibration and factory test data, ensuring optimum Ievels of performance are realized.

• Laser and Plasma research • EMC and EMI research • Semiconductor gate switching • Power system barmollies and transients • Lightning research and simulation testing • Capacitor and electrostatic discharges • Corona wire discharge • Partial Discharge measurement • Critical monitoring of current fluctuations

AMS Technologies has invested into the pickaCT program offering customers off the shelf availability of a large number of different HF current transformers. The product range offers the measurement of currents from microamps to 20K amps, at frequencies ranging from 0.5 Hz to 500 MHz.  The selection guide to these preferred current transformers can be found on the next page or online:  www.amstechnologies-webshop.com/current-transformer

For large volume applications we recommend to call your regional AMS Technologies office, so that we can tailor a solution based on your technical needs.

Close filters
  •  
from to
Save
Products 15
1 From 2
No results were found for the filter!
High Precision HF Current Transformer CT-D0.25-B Max Peak 4000A
High Precision HF Current Transformer CT-D0.25-B Max Peak 4000A
The Magnelab Current Transformer (CT) provides an accurate, non destructive (non...
€715.00

Delivery time 45 workdays

High Precision HF Current Transformer CT-D1.0-B Max Peak 1000A
High Precision HF Current Transformer CT-D1.0-B Max Peak 1000A
The Magnelab Current Transformer (CT) provides an accurate, non destructive (non...
€715.00

Delivery time 45 workdays

High Precision HF Current Transformer CT-C5.0-B Max Peak 200A
High Precision HF Current Transformer CT-C5.0-B Max Peak 200A
The Magnelab Current Transformer (CT) provides an accurate, non destructive (non...
€620.00

Delivery time 45 workdays

High Precision HF Current Transformer CT-C0.1-B Max Peak 10000A
High Precision HF Current Transformer CT-C0.1-B Max Peak 10000A
The Magnelab Current Transformer (CT) provides an accurate, non destructive (non...
€620.00

Delivery time 45 workdays

High Precision HF Current Transformer CT-C1.0-B Max Peak 1000A
High Precision HF Current Transformer CT-C1.0-B Max Peak 1000A
The Magnelab Current Transformer (CT) provides an accurate, non destructive (non...
€620.00

Delivery time 45 workdays

High Precision HF Current Transformer CT-E0.5-B Max Peak 2000A
High Precision HF Current Transformer CT-E0.5-B Max Peak 2000A
The Magnelab Current Transformer (CT) provides an accurate, non destructive (non...
€760.00

Delivery time 45 workdays

High Precision HF Current Transformer CT-B1.0-B Max Peak 1000A
High Precision HF Current Transformer CT-B1.0-B Max Peak 1000A
The Magnelab Current Transformer (CT) provides an accurate, non destructive (non...
€715.00

Delivery time 45 workdays

High Precision HF Current Transformer CT-D0.1-S Max Peak 10000A
High Precision HF Current Transformer CT-D0.1-S Max Peak 10000A
The Magnelab Current Transformer (CT) provides an accurate, non destructive (non...
€715.00

Delivery time 45 workdays

High Precision HF Current Transformer CT-C5.0-S Max Peak 200A
High Precision HF Current Transformer CT-C5.0-S Max Peak 200A
The Magnelab Current Transformer (CT) provides an accurate, non destructive (non...
€620.00

Delivery time 45 workdays

High Precision HF Current Transformer CT-D0.5-B Max Peak 2000A
High Precision HF Current Transformer CT-D0.5-B Max Peak 2000A
The Magnelab Current Transformer (CT) provides an accurate, non destructive (non...
€715.00

Delivery time 45 workdays

High Precision HF Current Transformer CT-E2.5-B Max Peak 400A
High Precision HF Current Transformer CT-E2.5-B Max Peak 400A
The Magnelab Current Transformer (CT) provides an accurate, non destructive (non...
€760.00

Delivery time 45 workdays

High Precision HF Current Transformer CT-E0.1-S Max Peak 10000A
High Precision HF Current Transformer CT-E0.1-S Max Peak 10000A
The Magnelab Current Transformer (CT) provides an accurate, non destructive (non...
€760.00

Delivery time 45 workdays